Premium Fire Door Grey Intumescent Acrylic Sealant
Our premium-grade intumescent acrylic sealant is designed to swell and effectively prevent the passage of fire and smoke. With the capability of providing up to 4 hours of fire resistance, it is both fire and acoustic-rated. This sealant is conveniently supplied in a 310ml recycled plastic cartridge.
Features & Benefits:
- Halogen-free, polymer-based formulation
- Offers fire protection for FD30-120 fire-rated door sets with FAS Fire Door Foam™
- Acoustic tested, achieving 55dB Rw
- Compatible with standard plastic and timber packers
- Long-lasting flexibility with a 12.5% joint movement capability
- Grey colour chart code RAL 7035
- Other colour options available: orange, brown, and white for next-day delivery
Areas of Application:
- Ideal for cavity gap filling and perimeter pointing in partition joints and between fire door frames, screens, and walls
- Provides 30-60 minutes of fire resistance for 5mm gaps or below without backing
- Offers 30-120 minutes of fire resistance for gaps up to 25mm when used with FAS Fire Door Foam™ or stone mineral fibre wool
- Suitable for timber frames: softwood (FD30), hardwood (FD60)
Fire Rating:
Extensively fire tested for 30-120 minutes under BS 476: Pt 20 & 22: 1987 and BS EN 1634-1: 2014
Acoustic Rating:
- Acoustic tested under BS EN ISO 10140-2:2010
- Complies with the requirements of Approved Document E
Certifire Certificate:
CF5840
Shelf Life
18 months if stored in accordance with storage guidance.
Storage & Disposal
- Cartridges or foil sausages can be stored for at least 18 months from the production date when stored in a cool, dry environment, in original unopened containers, and at temperatures between 2⁰C and 30⁰C. Do not allow it to freeze.
- These products should not be left in an overheated environment, in temperatures above +50˚C or exposed to direct sunlight.
- Empty cartridges or foils should be disposed of appropriately in line with local regulations. Refer to the Material Safety Data Sheet for more information.
Maintenance
- Recorded inspection should be conducted in line with the maintenance and inspection schedule that is defined for the building or project. These should be conducted and recorded by competent individuals.
- Where the product is damaged or tampered with, a new product should be installed with the installation guidance.
Product Information
All website information and technical data reflect the latest versions.
FAS Fire Door Intumescent Acrylic Sealant Certifire Certificate - CF5840
FAS Fire Door Intumescent Acrylic Sealant Material Safety Data Sheet
FAS Fire Door Intumescent Acrylic Sealant Technical Data Sheet
FAS Fire Door Intumescent Acrylic Sealant Installation Guide