A premium grade intumescent acrylic sealant that swells to prevent the passage of fire and smoke. It can provide up to 4 hours of fire resistance and is fire, smoke and acoustic rated. Supplied in a 310ml recycled plastic cartridge.
Features & Benefits
-
A halogen-free, polymer-based sealant
-
60 minutes fire-rated
-
Acoustic tested to achieve 55dB Rw.
-
Compatible with standard plastic and timber packers.
-
Long-lasting flexibility.
-
12.5% joint movement capability.
-
Fire protection for FD30-120 fire-rated door sets with FAS Fire Door Foam™.
-
Available in 600ml foil sausage.
-
Our Intumescent Acrylic Sealant is also available in brown and orange for next-day delivery, and grey on special orders.
Areas of Application
-
Cavity gap filling and perimeter pointing in partition joints and between fire door frames, screens, and walls.
-
Provides 30-60 minutes of fire resistance for 5mm gaps or below without backing, and 30-120 minutes of fire resistance for gaps up to 25mm with FAS Fire Door Foam™ or stone mineral fibre wool.
-
Timber frames - softwood (FD30), hardwood (FD60).
Fire Rating
Extensively fire tested to 30-120 minutes with fire doorsets in accordance with BS 476: Pt 20 & 22: 1987 and BS EN 1634-1: 2014.
Certifire Certificate
CF5840
Acoustic Rating
Acoustic tested in accordance with BS EN ISO 10140-2:2010.
Comply with Approved Document E.
Shelf Life
18 months if stored in accordance with storage guidance.
Storage & Disposal
- Cartridges or foil sausages can be stored for at least 18 months from the production date when stored in a cool, dry environment, in original unopened containers, and at temperatures between 2⁰C and 30⁰C. Do not allow it to freeze.
- These products should not be left in an overheated environment, in temperatures above +50˚C or exposed to direct sunlight.
- Empty cartridges or foils should be disposed of appropriately in line with local regulations. Refer to the Material Safety Data Sheet for more information.
Maintenance
- Recorded inspection should be conducted in line with the maintenance and inspection schedule that is defined for the building or project. These should be conducted and recorded by competent individuals.
- Where the product is damaged or tampered with, a new product should be installed with the installation guidance.
Product Information
All website information and technical data reflect the latest versions.
FAS Fire Door Intumescent Acrylic Sealant Certifire Certificate - CF5840
FAS Fire Door Intumescent Acrylic Sealant Material Safety Data Sheet
FAS Fire Door Intumescent Acrylic Sealant Technical Data Sheet
FAS Fire Door Intumescent Acrylic Sealant Installation Guide